Hi John,
thanks for the link.  Sending the printer cmds works fine.  he's able to set 
the lines/page and etc but what happens is after the labels have finished 
printing (ie after the NPR rpt finishes printing), Meditech sends a series of 
it's own printer commands which resets the lines/page and several other 
parameters.  when the user presses the page feed button on the printer, it form 
feeds too many labels because it now thinks it has 8 ½ x 11 paper in it.
 
It's a genicom 3860 btw.
 
He found out NPR was sending printer commands because
1. the printer was being reset to 8 ½ x 11 paper and
2. we redirected the NPR rpt to a virtual printer (his PC) which showed the 
command codes at the end of the report.  Oddly enough, the command codes don't 
get sent if the report is printed to DOWNLOAD and EFF NO and SFF NO are used.
After seeing the cmds displayed in #2 (above) our NPR report writer recognized 
the command codes as being the default LPI, CPL, etc Meditech uses in it's NPR 
reports.
 
Randy

>>> "Toop, John" <[EMAIL PROTECTED]> 1/15/2007 8:02:17 am >>>
Hi Randy,

The following kb article is how to reset the printer

https://www.meditech.com/kb/Custform.ASP?urn=15712 

But I'm not sure that is the solution you need. At the end of the print
job MEDITECH is reseting the print to it's defaults. Genicom makes a lot
of different printers (lasers and dot matrix too) and your specific
question did provide specific codes but did not give the model number.

How did he determine the codes being sent to the printer? Why is that
significant?

John Toop
Humber River Regional Hospital
Toronto, Ontario
(416) 249-8111 x 8019
[EMAIL PROTECTED]

DISCLAIMER: **Confidential Communications. If you have received this
message in error, please notify me and delete the original.**



CONFIDENTIALITY NOTICE:  The information contained in this e-mail is privileged 
and confidential, and is intended only for the use of the individual or entity 
named above.  If you are not the intended recipient, you are notified that any 
disclosure, copying, distribution, electronic storage or use of this 
communication is prohibited.  If you received this communication in error, 
please notify us immediately by e-mail, attaching the original message, and 
delete the original message from your computer and any network to which your 
computer is connected.
=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=*=
To subscribe or unsubscribe to the meditech-l, visit MTUsers.COM.

To check the status of the meditech-l, visit MTUsers.NET.

For help, email [EMAIL PROTECTED]
______________________________________
meditech-l mailing list
[email protected]
http://mtusers.com/mailman/listinfo/meditech-l

Reply via email to