Dear Szymon,

Just glancing at your graph, those oscillations resemble very much the 
oscillations in one of the Meep examples:

http://ab-initio.mit.edu/wiki/index.php/Meep_Tutorial/Band_diagram%2C_resonant_modes%2C_and_transmission_in_a_holey_waveguide

The explanation they give is: "There is also some high-frequency 
oscillation visible at the left of the plot, which is a numerical 
artifact due to our pulse not having enough amplitude in that range."

It looks like you are seeing a similar thing.

George

Szymon Lis wrote:
> Hi Meep users,
>
> My problem in meep are strange oscillation in reflection spectrum form cavity 
> waveguide. The reflection graph are attached. That is my the best result. 
> When I try different resolution, or/and various distances between source and 
> phc oscillation are bigger. Even reach 1.4 reflection!. I don't know what 
> exactly it is? Numerical error? How to avoid it?
>
> Thank you.
> Szymon
>
>
> ___________
> Szymon Lis
> Photonics Group
> Faculty of Microsystem Electronics and Photonics
> Wroclaw University of Technology
> ul. Janiszewskiego 11/17, 50-372 Wroclaw, POLAND
>
> Tel. +48 (71) 320 3735
> Fax. +48 (71) 328 3504
>   
>
> ------------------------------------------------------------------------
>
> ------------------------------------------------------------------------
>
> _______________________________________________
> meep-discuss mailing list
> [email protected]
> http://ab-initio.mit.edu/cgi-bin/mailman/listinfo/meep-discuss

_______________________________________________
meep-discuss mailing list
[email protected]
http://ab-initio.mit.edu/cgi-bin/mailman/listinfo/meep-discuss

Reply via email to