Dear Meep users, I want to calculate nonlinear index change. Firstly, I apply to source in linear system. After than I look at the h5 file to see field profile and what the magnitude of electric field is at the desired point.
So, I calculate intensity with I= |E|^2 / 2*eta than index change is delta_n= n2*I is this way of thinking correct? Electrical-Electronics Eng.Dept. 20070 Kinikli-Denizli TURKEY Tel: (+90 258) 296 3213 _______________________________________________ meep-discuss mailing list [email protected] http://ab-initio.mit.edu/cgi-bin/mailman/listinfo/meep-discuss