On Dec 24, 2010, at 3:40 AM, Özgür Önder KARAKILINÇ wrote:
So, should I do synchronization of fields when I use add-flux function ?
No, the Fourier transforms in add-flux automatically multiply the fields by the phase for the correct times; no synchronization is needed.
_______________________________________________ meep-discuss mailing list [email protected] http://ab-initio.mit.edu/cgi-bin/mailman/listinfo/meep-discuss