Does anyone know that the boost range is suppose to be for EXA and Z18 Map sensors?
I thought they would be 1 bar max... but nope, just tested one of each here now and got around 5.5volts out of them at 30psi and 6 volts at 35psi (had to stop there cause my boost gauge was going off scale :) I would have thought it would be maxing out at around 5 volts at 14psi (1 bar)... but nope - 14psi actually = 3.9volts and the voltage was still increasing at 35psi... 0 to 10psi is not linear, but 10psi (3.5v) up is linear (eg.. 0.1 volt per 1 psi) James -- ----------------------------------------------------------- James Fitness Director Data Scribe Australia Pty Ltd http://www.datascribe.com.au Computers, Peripherals and Supplies Ozdat Online Webmaster http://www.ozdat.com --membersozdat------------------------------------------------------- OZDAT Mailing List Please Note:- Send (un)subscribe requests to [EMAIL PROTECTED] Send submissions to [EMAIL PROTECTED] No unauthorised redistribution of this email http://www.ozdat.com/ozdatonline/index.htm http://www.ozdat.com/ozdatonline/listindex.html http://www.mail-archive.com/[EMAIL PROTECTED]/ ---------------------------------------------------------------------