Does anyone know that the boost range is suppose to be
for EXA and Z18 Map sensors?

I thought they would be  1 bar max... but nope,  just tested
one of each here now and got around 5.5volts out of them at
30psi and 6 volts at 35psi (had to stop there cause my
boost gauge was going off scale :)

I would have thought it would be maxing out at around 5 volts
at 14psi (1 bar)... but nope - 14psi actually = 3.9volts
and the voltage was still increasing at 35psi...

0 to 10psi is not linear, but 10psi (3.5v) up is linear (eg.. 0.1 volt
per 1 psi)


James


--
-----------------------------------------------------------