That's the advantage of Cathey Special Blend. 
If it leaks, just add propane until the pressures are good again. 

BTW, I was looking at Linde Gas this morning, and they claimed their R290 was
97.5% propane. Any reason why I should pay dollars per pound for 97% refrigerant
grade when I get pounds per dollar of HD5 which is guaranteed to be 90% or
higher, with up to 5% butanes and methane and 5% propylene? I already have over
3000lb of HD5 in bulk (500 gallon) cylinders. The only thing that might be
bothersome is the 0-5% propylene.

Mitch. 

> On November 27, 2016 at 10:39 AM "Kaleb C. Striplin via Mercedes"
> <[email protected]> wrote:
> 
> 
> I have tried this and duracool and I just do not like the blends. If you have
> any sort of leak at all the different elements leak at different rates which
> changes the mix and it does not cool.