That was similar to the GM switch. Also, the GM blower high speed switch
had 30+ amperes running through a slip-on connection, which tended to
corrode, get loose, and consequently heat up and melt.

Tom Potter

-----Original Message-----
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of David Brodbeck
Sent: Thursday, September 21, 2006 12:35 PM
To: Mercedes Discussion List
Subject: Re: [MBZ] Falcon

Potter, Tom E wrote:
> Yes, but GM made NO effort to correct problems that existed for years
> (e.g. the high speed blower switch). Badge engineering and decals
seems
> to be their forte.
>   

1980s-1990s VWs are famous for their melting blower switches, too.  It
comes down to cheapness...the switch is adequate for a new blower, but
when they get old and start drawing more current, the switch heats up. 
A relay for the high speed would avoid the problem, but it'd cost an
extra few bucks per car.  Multiply that by a million or so cars and
you're talking about real money.