Thanks, Daiane,

On 10/29/2014 10:56 AM, Daiane Angolini wrote:
> Use the same name convention for variable SOC used in other machines.
> This mismatch was highlighted during the automatic generation of supported
> machine list for FSL Community BSP Release Notes 1.7.
> 
> Signed-off-by: Daiane Angolini <[email protected]>
> ---
>  conf/machine/nitrogen6x-lite.conf | 2 +-
>  1 file changed, 1 insertion(+), 1 deletion(-)
> 
> diff --git a/conf/machine/nitrogen6x-lite.conf 
> b/conf/machine/nitrogen6x-lite.conf
> index 07f73b5..f17cff0 100644
> --- a/conf/machine/nitrogen6x-lite.conf
> +++ b/conf/machine/nitrogen6x-lite.conf
> @@ -1,6 +1,6 @@
>  #@TYPE: Machine
>  #@NAME: Boundary Devices Nitrogen6X Lite
> -#@SOC: i.MX6 Solo
> +#@SOC: i.MX6S
>  #@DESCRIPTION: Machine configuration for Boundary Devices Nitrogen6X Lite
>  #@MAINTAINER: Eric Nelson <[email protected]>
>  
> 

Acked-by: Eric Nelson <[email protected]>
-- 