On 8 November 2017 at 18:17, Vineeth Chowdhary Karumanchi <[email protected]> wrote: > Hi Manju, > > > question on similar lines, How can I change SERIAL_CONSOLE a part from > MACHINE conf ?
Since its set with "=" in these machine confs if you want to set it before (e.g. at local.conf) you will need to override it with something like: SERIAL_CONSOLE_forcevariable = "..." Or probably more practically, use the machine override. This way you could define multiple serial console values for different machines. e.g. SERIAL_CONSOLE_zcu102-zynqmp = "a" SERIAL_CONSOLE_other-machine = "b" Regards, Nathan > > Thanks > VIneeth > > On 11/7/2017 6:53 AM, Manjukumar Matha wrote: >> >> There are instances when serial console check if required to disable >> consoles when it is not defined by SERIAL_CONSOLES. >> >> Signed-off-by: Manjukumar Matha <[email protected]> >> --- >> conf/machine/zcu102-zynqmp.conf | 1 + >> 1 file changed, 1 insertion(+) >> >> diff --git a/conf/machine/zcu102-zynqmp.conf >> b/conf/machine/zcu102-zynqmp.conf >> index e6d66cd..dd61884 100644 >> --- a/conf/machine/zcu102-zynqmp.conf >> +++ b/conf/machine/zcu102-zynqmp.conf >> @@ -13,6 +13,7 @@ MACHINE_FEATURES = "rtc ext2 ext3 vfat usbhost" >> UBOOT_MACHINE = "xilinx_zynqmp_zcu102_revB_defconfig" >> SERIAL_CONSOLE = "115200 ttyPS0" >> +SERIAL_CONSOLES_CHECK = "${SERIAL_CONSOLES}" >> KERNEL_DEVICETREE = "xilinx/zynqmp-zcu102-revB.dtb >> xilinx/zynqmp-zcu102.dtb" >> > > > -- > _______________________________________________ > meta-xilinx mailing list > [email protected] > https://lists.yoctoproject.org/listinfo/meta-xilinx -- _______________________________________________ meta-xilinx mailing list [email protected] https://lists.yoctoproject.org/listinfo/meta-xilinx