Tom,
 
Here's one way:
 
 
@DECLARE#STR #info1
#INT #OPER

@START
#EVAL(#U0=0)
#EVAL(#OPER=JOS(step_num))
%
#IF(#U0=1)<*****START*****>
(#FILE CODED #DATE #SYSTIME)
(CODED ENGLISH FOR HITACHI SEIKI)
 B#FMT(#INDXB,T3.0)(**** INDEX ****)
N#OPER(#TLCMT)#EVAL(#DOFF=#DOFF+50)
 #MOV G90 G43 G#WKPLN X#XPOS Y#YPOS Z#ZPOS H#LOFF S#SPEED #SPNDL
 Z#ZPOST#NTOOL#TABLE(COOLANT,#COOLNT)
 
@TOOLCHG
#IF(#U0=1)<*****TOOLCHG*****>
#EVAL(#OPER=JOS(step_num))
G49G80M15#UPDATE(#FXD)
G91G30Z0
G91G30X0Y0M19
 M01
 M06
#IF(#WKSCHG=1)< B#FMT(#INDXB,T3.0)(**** INDEX ****)>#ELSE< M01>
N#OPER(#TLCMT)#EVAL(#DOFF=#DOFF+50)
 #MOV G90 G43 G#WKPLN X#XPOS Y#YPOS Z#ZPOS H#LOFF S#SPEED #SPNDL
 Z#ZPOST#NTOOL#TABLE(COOLANT,#COOLNT)
 
@END
#IF(#U0=1)<*****END*****>
G49G80M15#UPDATE(#FXD)
G91G30Z0
G91G30X0Y0M19 
M01
 M06
 M30
%
 
Hope this helps
 
Marty

 
 

-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]
Sent: Wednesday, March 15, 2000 5:24 PM
To: Smartcam Tech
Subject: [mfg-smartcam] Step number in TMP file


Hello,
 
Is there any way to access the step number with the tmp file? I would like
my "N" numbers in my nc code to
reflect the step number in the job plan.
 
 
 
Tom Cox 
[EMAIL PROTECTED] <mailto:[EMAIL PROTECTED]> 

======================================================================
To find out more about this mailing list including how to unsubscribe,
send the message "info mfg-smartcam" to [EMAIL PROTECTED]
======================================================================

Reply via email to