< #MOV>< #FDMODE>< X#XPOS>< Z#ZPOS>< F#FEED> After choosing your tool type, the first page that comes up is the Process Step page on there you can choose speed mode feet/min for your c.s.s. (G96) or rpm css cancel (G97). Under that is Feed Mode inch/rev (G99) or inch/min (G98). What you choose for each tool should output code accordingly.
Dave Wolfgang ----- Original Message ----- From: "John Coulston" <[EMAIL PROTECTED]> To: "'SmartCam'" <[EMAIL PROTECTED]> Sent: Friday, June 23, 2000 7:19 AM Subject: [mfg-smartcam] Turnning IPR feed rate? > How do I get IPR to be output for feed rate. Looked in SMF, should I use JOS field? > > > Thanks > > John > > ====================================================================== > To find out more about this mailing list including how to unsubscribe, > send the message "info mfg-smartcam" to [EMAIL PROTECTED] > ====================================================================== > ====================================================================== To find out more about this mailing list including how to unsubscribe, send the message "info mfg-smartcam" to [EMAIL PROTECTED] ======================================================================