Peter, There is no easy way to do this, but this is one method I've used. Create user integer variables, one for each tool station on your machine tool. These are to be used as flags to indicate if a tool has already been addressed. These flags are then checked in a conditional expression and will only output the tool information if still set to zero. Once the tool information for that station has been output that flag is set to one. The following example is for a machine with a 16 tool magazine.
@DECLARE #INT #T1 #INT #T2 #INT #T3 #INT #T4 #INT #T5 #INT #T6 #INT #T7 #INT #T8 #INT #T9 #INT #T10 #INT #T11 #INT #T12 #INT #T13 #INT #T14 #INT #T15 #INT #T16 @START #CALL(TOOLLIST) @TOOLLIST #IF(#U10=1)<***** THIS IS THE TOOL LIST SECTION *****> #EVAL(#U17=1) #EVAL(#U18=0) #REPEAT(TOTEL())< #EVAL(#U19=JTOOL(#U17) #IF(#U19>0,AND#U19<>#U18)<#CALL(TOOLLIST2)> #EVAL(#U18=#U19) #EVAL(#U17=#U17+1)> @TOOLLIST2 #IF(#U19=1)<#IF(#T1=1)<#EXITC>#ELSE<#EVAL(#T1=1)>> #IF(#U19=2)<#IF(#T2=1)<#EXITC>#ELSE<#EVAL(#T2=1)>> #IF(#U19=3)<#IF(#T3=1)<#EXITC>#ELSE<#EVAL(#T3=1)>> #IF(#U19=4)<#IF(#T4=1)<#EXITC>#ELSE<#EVAL(#T4=1)>> #IF(#U19=5)<#IF(#T5=1)<#EXITC>#ELSE<#EVAL(#T5=1)>> #IF(#U19=6)<#IF(#T6=1)<#EXITC>#ELSE<#EVAL(#T6=1)>> #IF(#U19=7)<#IF(#T7=1)<#EXITC>#ELSE<#EVAL(#T7=1)>> #IF(#U19=8)<#IF(#T8=1)<#EXITC>#ELSE<#EVAL(#T8=1)>> #IF(#U19=9)<#IF(#T9=1)<#EXITC>#ELSE<#EVAL(#T9=1)>> #IF(#U19=10)<#IF(#T10=1)<#EXITC>#ELSE<#EVAL(#T10=1)>> #IF(#U19=11)<#IF(#T11=1)<#EXITC>#ELSE<#EVAL(#T11=1)>> #IF(#U19=12)<#IF(#T12=1)<#EXITC>#ELSE<#EVAL(#T12=1)>> #IF(#U19=13)<#IF(#T13=1)<#EXITC>#ELSE<#EVAL(#T13=1)>> #IF(#U19=14)<#IF(#T14=1)<#EXITC>#ELSE<#EVAL(#T14=1)>> #IF(#U19=15)<#IF(#T15=1)<#EXITC>#ELSE<#EVAL(#T15=1)>> #IF(#U19=16)<#IF(#T16=1)<#EXITC>#ELSE<#EVAL(#T16=1)>> #EVAL(#S19=TDESC(#U19)) #EVAL(#V19=TLDIA(#U19)) #EVAL(#V18=TLEN(#U19)) #EVAL(#V17=TLOFF(#U20)) ( Tool matrix location =#U19 Tool Diameter.=#V19 Tool description = #S19 Tool Length =#U20) @ ============================================= Fred Lauzus, CAM Programming Coordinator High Steel Structures, Incorporated mailto:[EMAIL PROTECTED] http://www.highsteel.com ============================================= -----Original Message----- From: Bui, Peter [mailto:[EMAIL PROTECTED]] Sent: Tuesday, April 24, 2001 2:15 AM To: SmartCAM List (E-mail) Subject: [mfg-smartcam] Tool List Hi all, I've tried out this Tool List, and found that if there is more than one occurrences of a tool, the info for that tool will be output again. How can this be prevented? Please help! @START #CALL(TOOLLIST) @TOOLLIST #IF(#U10=1)<***** THIS IS THE TOOL LIST SECTION *****> #EVAL(#U17=1) #EVAL(#U18=0) #REPEAT(TOTEL())< #EVAL(#U19=JTOOL(#U17) #IF(#U19>0,AND#U19<>#U18)< #EVAL(#S19=TDESC(#U19)) #EVAL(#V19=TLDIA(#U19)) #EVAL(#V18=TLEN(#U19)) #EVAL(#V17=TLOFF(#U20)) ( Tool matrix location =#U19 Tool Diameter.=#V19 Tool description = #S19 Tool Length =#U20)> #EVAL(#U18=#U19) #EVAL(#U17=#U17+1)> @ Thanks Peter Bui CRANE ELDEC Corporation Phone: (425) 743-1313 Ext. 8758 FAX: (425) 743-8549 Email: [EMAIL PROTECTED] <mailto:[EMAIL PROTECTED]> Web Page: www.ELDEC.com <http://www.ELDEC.com> ====================================================================== To find out more about this mailing list including how to unsubscribe, send the message "info mfg-smartcam" to [EMAIL PROTECTED] ====================================================================== ====================================================================== To find out more about this mailing list including how to unsubscribe, send the message "info mfg-smartcam" to [EMAIL PROTECTED] ======================================================================