Does anyone know if there is a command to stop a code generator dead in its tracks?
What I'm trying to do is this: I am creating program cover sheets that look like the beginning of my program listings (i.e., with Part #, comments, etc.). To do this I create a copy of the TMP file, dump all the sections that are not needed and then code thru a macro. This works great on our milling machines, where we have only one TMP and one SMF, but when I try to do the same on our mill/turn machines that have master and slave code gens, I get actual program output from the slave generator. Anyone have any ideas? I've hit a dead end. Regards, Stephen Alfaro Manufacturing Engineering Group Flowserve Corp - Engineered Pump Division Los Angeles, California ====================================================================== To find out more about this mailing list including how to unsubscribe, send the message "info mfg-smartcam" to [EMAIL PROTECTED] ======================================================================