Group everything in your PM4 file and "save as" some filename. (Grouped elements only)
Open a brand new PM4 and merge in your stuff. Check functions to make sure no errors, and save the whole thing.
Should work, let us know,
Mark Chambers
At 09:14 AM 8/30/02 , you wrote:
While using the PolyarcFit function I am receiving an -Max number of work planes already in use- error. I have Killed all planes (which leaves only XY,YZ AND XZ)and still nothing. Its as though they are being stored somewhere and not displayed. I must be doing something wrong. any ideas?
Lee Greer
CAD\CAM department
Midwest Precision Tool & Die