I think the socketless hose is proofed out to 300psi with the proper socketless fitting barbs so it's not likely to be an issue. I used it for oil and coolant lines but I used braded stainless for the fuel lines, less likely to be cut by sharp objects or metal edges. The braded stainless tends to saw through anything it vibrates or rubs against though.
Bob ----- Original Message ----- From: "Russ" <[EMAIL PROTECTED]> To: "Russ" <[EMAIL PROTECTED]> Cc: "Miata Power List" <[email protected]> Sent: Thursday, April 03, 2008 11:04 AM Subject: Fuel Lines, etc. > One note on the fuel lines... Last night, I installed a bit of the -6 > AN socketless hose I'm using. I was once worried about this stuff > leaking without a clamp. Aeroquip says specifically not to clamp it. > After working hard to get 2 ends onto a section of hose, I'm now > confident it'll hold as designed. :-) > > > A built/race motor doesn't necessarily create a ton more power, it > withstands it. > _______________________________________________ > Miatapower mailing list > [email protected] > http://list.miatapower.net/cgi-bin/mailman/listinfo/miatapower _______________________________________________ Miatapower mailing list [email protected] http://list.miatapower.net/cgi-bin/mailman/listinfo/miatapower