Hi, Try using GetNext instead of Get and see what the agent returns in that case.
Also, the OID specified seems wrong. OID 1.3.6.1.6.3.11.2.1.3 corresponds to "snmpUnknownPDUHandlers" in SNMP-MPD-MIB. The "sysName" field in SNMPv2-MIB instead has OID 1.3.6.1.2.1.1.5. Cheers, /Per On mon, 2005-07-04 at 15:14 +0100, Bubul Ghoshal wrote: > Hi, > I just wanted to test the working of SNMPv3. So i chose Mibble MIB > Browser. I did the following settings > Host IP Address : 172.16.2.112 > Port Number : 161 > UserName : ss > Authentication : None > Privacy : None > Context Name : > Context Engine : > When i tried to get the value for "sysName", the OID value was > changed to 1.3.6.1.6.3.11.2.1.3.0 and i got a value 6441 as shown in > the output > GET: 1.3.6.1.6.3.11.2.1.3.0: 6441 > But when i performed the same operation for the same configuration > using some othe MIB Browser i got the correct result for SNMPv3. Can > any one sugest where am i going wrong and the ways to get values for > SNMPv3 compatible devices using Mibble MIB Browser. > > Thanks and Regards, > Bubul. _______________________________________________ Mibble-users mailing list Mibble-users@nongnu.org http://lists.nongnu.org/mailman/listinfo/mibble-users