Having an issue on a link between two 750s where I’m getting on the 750Gr2 end; Database Description packet has init bit set in middle of an exchange messages all the time. This link will get to the point it doesn’t pass traffic anymore and about the only way to get it to run again is do a hard reboot. The other end is a 750GL. Between the two are UBNT Titaniums in bridge mode. Everything is been changed out at both ends except the 750GL. OSPF is set for point to point since it is basically wireless between the two 750s. The same setup exists for another link off the Gr2 and I do not get that message for that neighbor nor do I get it through the Mimosa bridge off that router. Running v6.35 on all of them.
Any clues what the cause of this is? -- Terri Kelley Network Engineer 254-697-6710 Farm to Market Broadband -------------- next part -------------- An HTML attachment was scrubbed... URL: <http://mail.butchevans.com/pipermail/mikrotik/attachments/20160721/417e7013/attachment.html> _______________________________________________ Mikrotik mailing list Mikrotik@mail.butchevans.com http://mail.butchevans.com/mailman/listinfo/mikrotik Visit http://blog.butchevans.com/ for tutorials related to Mikrotik RouterOS