Yes we use Netonix with B5C's so far, soon B11's. Has Adair said, 48VH. We have had nothing but good experience with them.
Just a note we do pay close attention to the electrical short warnings when plugging in and unplugging PoE based devices, especially the HV devices like Mimosa and Airfibers. Have power on the port turned off when unplugging and plugging in to avoid any risk of damage. This is based on Netonix warning that comes with the switch. -----Original Message----- From: mimosa-boun...@wispa.org [mailto:mimosa-boun...@wispa.org] On Behalf Of Brent Smith Sent: Friday, August 05, 2016 9:05 AM To: mimosa@wispa.org Subject: [Mimosa] B11 and Netonix Are these two compatible and what power setting do I need to use for it? -- Brent Smith Network Technician New Lisbon Broadband and Communications www.nlbc.com (765)332-2887 MTCNA MTCWE -- _______________________________________________ Mimosa mailing list Mimosa@wispa.org http://lists.wispa.org/mailman/listinfo/mimosa --- This email has been checked for viruses by Avast antivirus software. https://www.avast.com/antivirus _______________________________________________ Mimosa mailing list Mimosa@wispa.org http://lists.wispa.org/mailman/listinfo/mimosa