LIU Hao wrote:

> 在 2026-9-23 11:35, Kirill Makurin 写道:
>> Hm, you're right. Stored thread ID is used for the following:
>>
>> 1. Ownership check in `pthread_mutex_unlock`; using `ReleaseMutex` alone 
>> would be sufficient as it fails
>> if calling thread does not own the mutex.
>> 2. Avoid recursive locking for error-checking mutexes (fails with `EDEADLK`).
>> 3. Handle lock count in user mode for recursive mutexes.
>>
>> We really only need it for case 2. Is there a way to check whether calling 
>> thread owns the mutex without
>> recursively locking it?
>
> Likely no. There's a syscall named `NtQueryMutant` which returns that 
> information, but there's no public
> Windows API for it.

That is unfortunate.

> An alternative approach is that, for a non-recursive robust mutex, there 
> should also be a thread ID
> field, such that `pthread_mutex_lock()` always calls `WaitForSingleObject()` 
> first to detect a potential
> dead owner; after the call returns `WAIT_OBJECT_0`, it can use the thread ID 
> field to check whether the
> call is recursive, and if so, it will release the mutex and return an error.

I had something like this in mind. Let's try this approach then.

>>  > Because a Windows Mutex object is recursive itself, it's probably not 
>> necessary record this information
>>  > in user mode?
>>
>> Yes, we can do this. My idea was that handling lock count in user mode may 
>> be a little faster: we avoid
>> extra calls to `WaitForSingleObject` and `ReleaseMutex` on recursive 
>> lock/unlock. I'll go with your
>> judgment on this.
>
> For recursive robust mutex, there's no need to keep a user-mode recursion 
> counter, I think.

Ok. I'll send new version of changes later.

- Kirill Makurin

_______________________________________________
Mingw-w64-public mailing list
[email protected]
https://lists.sourceforge.net/lists/listinfo/mingw-w64-public

Reply via email to