how does openbsd's RAID support stack up to the other *BSDs? On 9/10/05, Theo de Raadt <[EMAIL PROTECTED]> wrote: > I thought it was time to give some details about the (minimal) RAID > management stuff coming in OpenBSD 3.8. Most of this code has been > written by Marco Peereboom with some help from David Gwynne and > Michael Shalayeff. Moral support and direction from me and Bob Beck > who has a pile of these AMI setups. > > Here is a demonstration. First, a piece of dmesg output, so that we can > see which device is going to be handled: > > ami0 at pci1 dev 8 function 0 "Symbios Logic MegaRAID" rev 0x01: apic 9 int 8 > (irq 10) Dell 518/64b/lhc > ami0: FW 350O, BIOS v1.09, 128MB RAM > ami0: 2 channels, 0 FC loops, 2 logical drives > scsibus2 at ami0: 40 targets > sd0 at scsibus2 targ 0 lun 0: <AMI, Host drive #00, > SCSI2 0/direct fixed > sd0: 349400MB, 44542 cyl, 255 head, 63 sec, 512 bytes/sec, 715571200 sec total > sd1 at scsibus2 targ 1 lun 0: <AMI, Host drive #01, > SCSI2 0/direct fixed > sd1: 349400MB, 44542 cyl, 255 head, 63 sec, 512 bytes/sec, 715571200 sec total > scsibus3 at ami0: 16 targets > ses0 at scsibus3 targ 6 lun 0: <DELL, PV22XS, E.17> SCSI3 3/processor fixed > scsibus4 at ami0: 16 targets > ses1 at scsibus4 targ 6 lun 0: <DELL, PV22XS, E.17> SCSI3 3/processor fixed > > OK, this is an AMI raid controller. It has come up with 3 scsi > busses; one for the virtual RAID volumes which there are two of, and > two SCSI busses which match the real SCSI busses that are on the > controller (to expose the SES or SAFTE enclosure management > controllers, and so that we can talk pass-through to the real disks). > > If we wish to probe further details, we use > > # bioctl ami0 > Volume Status Size Device > ami0 0 Online 366372454400 sd0 RAID5 > 0 Online 73403465728 0:0.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 1 Online 73403465728 0:2.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 2 Online 73403465728 0:4.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 3 Online 73403465728 0:8.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 4 Online 73403465728 1:10.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 5 Online 73403465728 1:12.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > ami0 1 Online 366372454400 sd1 RAID5 > 0 Online 73403465728 0:1.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 1 Online 73403465728 0:3.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 2 Online 73403465728 0:5.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 3 Online 73403465728 1:9.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 4 Online 73403465728 1:11.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 5 Online 73403465728 1:13.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > ami0 2 Unused 73403465728 1:14.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > ami0 3 Hot spare 73403465728 1:15.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > > Here we can see which physical drives are on the controller, and how > they are configured into volumes. Two volumes have been created, both > of which are rather large. The drives are on two scsi busses, for > instance, 1:12.0 means SCSI bus 1, scsi target 12, lun 0. With > additional options to bioctl(4), we could find out some more (mostly > irrelevant) information. > > There are also two additional devices which we know about: one is > unused (ie. not registered with the AMI firmware at the moment), and > one is a Hot Spare. > > Let's cause some havoc. First, I want to pick a drive that I am going > to unplug, to mimic a failure. Let's see... 1:9.0 looks good to me. > > # bioctl -b 1.9 ami0 > > When I look at the array, one of the drives is now blinking. I made > it blink just because I prefer to pull drives out of my sd1 > filesystems rather than the sd0 filesystems. And otherwise I wouldn't > be able to show off the blink support. Anyways, I pull that > particular drive. > > Immediately some churning starts, and if I re-run bioctl I can see what > has happened: > > # bioctl ami0 > Volume Status Size Device > ami0 0 Online 366372454400 sd0 RAID5 > 0 Online 73403465728 0:0.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 1 Online 73403465728 0:2.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 2 Online 73403465728 0:4.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 3 Online 73403465728 0:8.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 4 Online 73403465728 1:10.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 5 Online 73403465728 1:12.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > ami0 1 Degraded 366372454400 sd1 RAID5 > 0 Online 73403465728 0:1.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 1 Online 73403465728 0:3.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 2 Online 73403465728 0:5.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 3 Rebuild 73403465728 1:15.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 4 Online 73403465728 1:11.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 5 Online 73403465728 1:13.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > ami0 2 Unused 73403465728 1:14.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > > Drive 1:15 automatically became a part of the "sd1" volume, and is > currently rebuilding. If I access a filesysdtem on sd1, I will notice > that it is a little bit slower. > > Of course the RAID array is beeping so loudly I think my ears are going to > burst, so I must shut it up: > > # bioctl -a quiet ami0 > > When I reinsert the drive that I previously unplugged, I see: > > # bioctl ami0 > Volume Status Size Device > ami0 0 Online 366372454400 sd0 RAID5 > 0 Online 73403465728 0:0.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 1 Online 73403465728 0:2.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 2 Online 73403465728 0:4.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 3 Online 73403465728 0:8.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 4 Online 73403465728 1:10.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 5 Online 73403465728 1:12.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > ami0 1 Degraded 366372454400 sd1 RAID5 > 0 Online 73403465728 0:1.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 1 Online 73403465728 0:3.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 2 Online 73403465728 0:5.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 3 Rebuild 73403465728 1:15.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 4 Online 73403465728 1:11.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 5 Online 73403465728 1:13.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > ami0 2 Unused 73403465728 1:9.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > ami0 3 Unused 73403465728 1:14.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > > Drive 1:9 has come back as "Unused". Let's make it a Hot Spare, so that I can > use it later. > > # bioctl -H 1:9 ami0 > # bioctl ami0 > Volume Status Size Device > ami0 0 Online 366372454400 sd0 RAID5 > 0 Online 73403465728 0:0.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 1 Online 73403465728 0:2.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 2 Online 73403465728 0:4.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 3 Online 73403465728 0:8.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 4 Online 73403465728 1:10.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 5 Online 73403465728 1:12.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > ami0 1 Degraded 366372454400 sd1 RAID5 > 0 Online 73403465728 0:1.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 1 Online 73403465728 0:3.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 2 Online 73403465728 0:5.0 ses0 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 3 Rebuild 73403465728 1:15.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 4 Online 73403465728 1:11.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > 5 Online 73403465728 1:13.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > ami0 2 Hot spare 73403465728 1:9.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > ami0 3 Unused 73403465728 1:14.0 ses1 <MAXTOR ATLAS15K2_73SCA > JNZ6> > > Now if I get another failure, there is a drive to perform a failover to again. > > Earlier we had mentioned the SES and SAFTE enclosure monitors. Their > statistics > are also available as well. > > # sysctl hw.sensors > hw.sensors.0=ses0, psu0, OK, indicator, On > hw.sensors.1=ses0, psu1, OK, indicator, On > hw.sensors.2=ses0, fan0, OK, percent, 33.33% > hw.sensors.3=ses0, fan1, OK, percent, 33.33% > hw.sensors.4=ses0, fan2, OK, percent, 33.33% > hw.sensors.5=ses0, fan3, OK, percent, 33.33% > hw.sensors.6=ses0, temp0, OK, temp, 26.00 degC / 78.80 degF > hw.sensors.7=ses0, temp1, OK, temp, 25.00 degC / 77.00 degF > hw.sensors.8=ses0, temp2, OK, temp, 27.00 degC / 80.60 degF > hw.sensors.9==ses0, temp3, OK, temp, 28.00 degC / 82.40 degF > hw.sensors.10=ses1, psu0, OK, indicator, On > hw.sensors.11=ses1, psu1, OK, indicator, On > hw.sensors.12=ses1, fan0, OK, percent, 33.33% > hw.sensors.13=ses1, fan1, OK, percent, 33.33% > hw.sensors.14=ses1, fan2, OK, percent, 33.33% > hw.sensors.15=ses1, fan3, OK, percent, 33.33% > hw.sensors.16=ses1, temp0, OK, temp, 26.00 degC / 78.80 degF > hw.sensors.17=ses1, temp1, OK, temp, 25.00 degC / 77.00 degF > hw.sensors.18=ses1, temp2, OK, temp, 27.00 degC / 80.60 degF > hw.sensors.19=ses1, temp3, OK, temp, 28.00 degC / 82.40 degF > > We can use sensorsd(8) to watch these status indicators for problems. > When this code was first written, I used to toggle one of the RAID > enclosure power switches for kicks, just so that I could see the > values change. > > I would like to make it clear that for 3.8, this support will only > work for the ami(4) raid controllers. Hopefully some other people > will come helping us to make controllers from other vendors work too. > About half of the code is a framework to permit RAID controller > drivers to do the right thing. > > The amount of code to support this is very small compared to typical > vendor RAID management solutions. The functionality supplied is also > very basic, almost minimal. But this is done like this on purpose, > since we believe that we could support this functionality on all RAID > controllers in the same way, without special "but that controller is > so different" mindsets entering the picture. RAID management should > (and can be) be no more complicated than ifconfig managing network > interfaces. The typical administrator needs > > to know when something is wrong > automatic Hot Swap allocation on volume degrade > to blink and unblink drives (to find them), > to be able to upgrade newly inserted drives to Hot Swap status > to shut off the damn beeper. > > Everything else is just icing. These are the micro operations which > really matter. All other operations on the volumes make it OK to > reboot into the card BIOS. > > At this point in this mail, I would love to show the output of the > RAID array back in normal status, but it will take a couple of hours > for that volume to be rebuilt. > > If anyone is serious about attempting to write the back-end code for > another RAID driver already in our tree, please contact > [EMAIL PROTECTED] But don't bother him with other stuff... > >
-- John Kintaro Tate Mobile: 0413 348 815 (Yep, old number, but I have a new phone) Free OpenBSD shell accounts for all with no gimmicks. Just send your desired username and password to me, and I will create it. Personal Website: http://kintaro.noobify.com