> On Thu, 23 May 2019, Jan Vlach wrote:
> 
> > IIRC, pvscsi used to eat up first write to the paravirtual storage
> > device with VMware. Not sure what's the current situation as I tend to
> > use LSI Logic SAS.
> 
> I do not understand very much, but yes, something is being eaten up.
> 
> The fsck I mentioned before was not effective, I landed with a system
> with ro mounted root system. It was impossible to do anything reasonable
> with it.
> 
> pci3 at ppb2 bus 3
> vmwpvs0 at pci3 dev 0 function 0 "VMware PVSCSI" rev 0x02: apic 1 int 18
                            ^^^^^^^^^^^^^^^^^^^^^^^^^^
https://marc.info/?l=openbsd-misc&m=144899602327183&w=2

I think you're seeing this. Change the Storage adapter in VMware to LSI
Logic SAS or ask your VM provider to do this for you.