Adam PAPAI writes:
> Hello misc,
> 
> I have an IBM xSeries 335 machine with Dual Xeon processor and 2x73GB 
> SCSI Seagate Barracuda 10K rpm disc. I run OpenBSD 3.8 on it.
> 
> When I'm creating the raid array (raidctl -iv raid0), I get the 
> following error message:
> 
> sd0(mpt0:0:0): Check Condition (error 0x70) on opcode 0x28
>      SENSE KEY: Media Error
>           INFO: 0x224c10c (VALID flag on)
>       ASC/ASCQ: Read Retries Exhausted
>           SKSV: Actual Retry Count: 63
> raid0: IO Error.  Marking /dev/sd0d as failed.
> raid0: node (Rod) returned fail, rolling backward
> Unable to verify raid1 parity: can't read stripe.
> Could not verify parity.

Is this early in the initialization or late in the initialization?

Try doing:

 dd if=/dev/rsd0d of=/dev/null bs=10m 

and see if you get the same error message...  

Later...

Greg Oster