On 2026-11-03, Samuel Thibault <[email protected]> wrote: > Hello, > > David Gwynne, le mar. 03 nov. 2026 14:10:29 +1000, a ecrit: >> what physical interfaces are you using as ports in aggr(4) (and >> trunk(4))? > > They are > > bnx0 at pci1 dev 0 function 0 "Broadcom BCM5709" rev 0x20: apic 1 int 4 > bnx1 at pci1 dev 0 function 1 "Broadcom BCM5709" rev 0x20: apic 1 int 16 > bnx2 at pci2 dev 0 function 0 "Broadcom BCM5709" rev 0x20: apic 1 int 0 > bnx3 at pci2 dev 0 function 1 "Broadcom BCM5709" rev 0x20: apic 1 int 10 > >> generally, if an interface supports multiple rx rings, it >> will set a flowid on mbufs for you. > > It looks like it's not happening.
The bnx(4) driver doesn't support MSI or multiple rings. From what I read, BCM5709 hardware would do if the driver supported it. >> the diff below tries to fix the M_FLOWID setting in aggr_port_input(), >> and adds a link0 flag that enables packet parsing/hashing in a similar >> style to what trunk(4) did. you'll have to "ifconfig aggr0 link0" to >> enable it. Is there a benefit to hiding behind link0 rather than juat falling back if M_FLOWID is not set? -- Please keep replies on the mailing list.