Sebastian Reitenbach wrote:
I got such a storage device, mentioned in the subject. In the manual it
says, when I want to connect the storage to a PCI based hosts, I need a PCI
to dual differential UltraSCSI adapter, Model X6541A.
What you need is any differential UltraSCSI controller. The D1000 can have
its two SCSI buses joined and you can configure it so they don't have
repeating SCSI IDs... or if you have two differential UltrasCSI channels, you
can connect them separately.
However, the X6541A does work fine - I have one in a PowerEdge 1550, currently
connected to a D1000:
siop0 at pci2 dev 6 function 0 "Symbios Logic 53c875" rev 0x14: apic 3 int 13
(irq 3), using 4K of on-board RAM
scsibus2 at siop0: 16 targets
sd2 at scsibus2 targ 0 lun 0: <FUJITSU, MAA3182S SUN18G, 1907> SCSI2 0/direct
fixed
sd2: 17274MB, 7508 cyl, 19 head, 248 sec, 512 bytes/sec, 35378533 sec total
sd3 at scsibus2 targ 1 lun 0: <FUJITSU, MAA3182S SUN18G, 1907> SCSI2 0/direct
fixed
sd3: 17274MB, 7508 cyl, 19 head, 248 sec, 512 bytes/sec, 35378533 sec total
sd4 at scsibus2 targ 2 lun 0: <FUJITSU, MAA3182S SUN18G, 1907> SCSI2 0/direct
fixed
sd4: 17274MB, 7508 cyl, 19 head, 248 sec, 512 bytes/sec, 35378533 sec total
safte1 at scsibus2 targ 14 lun 0: <SYMBIOS, D1000, 2> SCSI2 3/processor fixed
siop1 at pci2 dev 6 function 1 "Symbios Logic 53c875" rev 0x14: apic 3 int 14
(irq 11), using 4K of on-board RAM
scsibus3 at siop1: 16 targets
sd5 at scsibus3 targ 8 lun 0: <FUJITSU, MAA3182S SUN18G, 1907> SCSI2 0/direct
fixed
sd5: 17274MB, 7508 cyl, 19 head, 248 sec, 512 bytes/sec, 35378533 sec total
sd6 at scsibus3 targ 9 lun 0: <FUJITSU, MAA3182S SUN18G, 1907> SCSI2 0/direct
fixed
sd6: 17274MB, 7508 cyl, 19 head, 248 sec, 512 bytes/sec, 35378533 sec total
sd7 at scsibus3 targ 10 lun 0: <FUJITSU, MAA3182S SUN18G, 1907> SCSI2 0/direct
fixed
sd7: 17274MB, 7508 cyl, 19 head, 248 sec, 512 bytes/sec, 35378533 sec total
safte2 at scsibus3 targ 15 lun 0: <SYMBIOS, D1000, 2> SCSI2 3/processor fixed
--
Matthew Weigel
hacker
unique & idempot.ent