sorry for the too late answer, but here we are now.

The not working call seems to have debugging enabled, so your temporary
solution didn't last long hm :-)

anyway, the other device answers with a RELEASE_COMPLETE with cause: 96
on our SETUP_ACKNOWLEGDE, which is very weird.. caue:96 means  "Missing
Information Element" .. I need to find out which Info Elements are
mandatory on SetupAck and will check

>Wed Aug  9 17:32:43 2006: P[ 1]  I IND :RELEASE_COMPLETE oad: dad: pid:3 
>state:WAITING4DIGS
>Wed Aug  9 17:32:43 2006: P[ 1]   --> channel:0 mode:NT cause:96 ocause:16 
>rad: cad:
>Wed Aug  9 17:32:43 2006: P[ 1]   --> info_dad: onumplan:0 dnumplan:0 
>rnumplan:0 cpnnumplan:0
>Wed Aug  9 17:32:43 2006: P[ 1]   --> caps:Speech pi:0 keypad: 
>sending_complete:0
>Wed Aug  9 17:32:43 2006: P[ 1]   --> screen:0 --> pres:0
>Wed Aug  9 17:32:43 2006: P[ 1]   --> addr:50010102 l3id:10041 b_stid:0 
>layer_id:50010180
>Wed Aug  9 17:32:43 2006: P[ 1]   --> facility:FAC_NONE out_facility:FAC_NONE
>Wed Aug  9 17:32:43 2006: P[ 1]   --> bc_state:BCHAN_CLEANED
>Wed Aug  9 17:32:43 2006: P[ 1]  hangup_chan
>

You wrote before that the problem occurs at least since 0.3.1-rc18,
didn't it occur before?


I wonder why the other device sometimes like our SETUP_ACK and sometimes
not.. what exact device is it?

Regards,

Christian

_______________________________________________
Misdn-asterisk mailing list
[email protected]
http://lists.beronet.com/cgi-bin/mailman/listinfo/misdn-asterisk

Reply via email to