Kai Ober wrote:
Christian Richter schrieb:
Kai Ober wrote:
okay, next question to conf file
option=<number>, master_clock
which port should i choose here and what is it exactly good for?
<number> should be the port which is connected to a TE port. It is
used to synchronize the hfcmulti driver with the clock from the PSTN
=> important for faxes !
ahh okay, I see. this results in following question:
When i have 2 cards, lets say each is a 4S0.
one is configured completely in TE mode (card 1) and one in NT
mode.(card 2)
both cards are connected via pcm bus
does card 2 get sync from card 1?
so can i put a fax-machine on card 2 and it gets synced from the
other card?
or have i to configure at least one TE and master_clocked port on each
card?
if the cards are wired via PCM it is quite enough to use one TE form
card 1 setted in master_clock mode. The second card will receive the
sync as pcm_slave.
okay, last question, important for hardware faxes, or software faxes?
both.
THX kai