Antonio Gallo wrote:
Christian Richter ha scritto:
it's important to use the timing from the ISDN Port, so on a X-Port BRI card, please set the master_clock option.

I've to set master_clock even when the i have only 1 BRI? Have i to set it also when i've an analog card FXO onto the same machine?
no on the single BRI you don't need it.


Ty in advance, Antonio


_______________________________________________
Misdn-asterisk mailing list
[email protected]
http://lists.beronet.com/cgi-bin/mailman/listinfo/misdn-asterisk




--
*******************************************