Dear MITK-IGT users,
we changed the IGTTimeStamp (see T18881 - https://phabricator.mitk.org/T18881
). The problem with the old time stamp was, that it returned a time stamp which
was not measured in milliseconds and which references depended on the operating
system. Additionally, two different time stamps were used (depending on the xml
or csv writer): the IGT time stamp and the ITK time stamp.
We changed the time stamp to chrono and made sure, that both
NavigationDataSetWriter (xml and csv) use the IGTTimeStamp.
Please use the method GetIGTTimeStamp (not GetTimeStamp) when using IGT. If you
experience any difficulties replaying your previously recorded tracking files
due to the changed time stamp, please let me know.
Best wishes,