Dear Anil, If I look at the code, the method actually does a 3-parameter LM fit: https://github.com/MIC-DKFZ/MITK-Diffusion/blob/master/Modules/DiffusionCore/Algorithms/Reconstruction/itkDiffusionIntravoxelIncoherentMotionReconstructionImageFilter.cpp#L447
I am not sure where the output on the clipboard originates from. Do you know anything about this, Michael & Paul? Peter ________________________________________ Von: ashetty <ashe...@bcm.edu> Gesendet: Mittwoch, 18. September 2019 18:55 An: mitk-users@lists.sourceforge.net Betreff: [mitk-users] IVIM module I have been using IVIM module to determine f, D and D* using 3-parameter fit. However, when I copy measurement points to excel, I see that it does first linear fit of D and f at high b, and then, fits for D*. Should this not do 3 parameters simultaneously using L-M method when I choose option of 3-parameter fit? Appreciate your answer. _anil -- Sent from: http://mitk-users.1123740.n5.nabble.com/ _______________________________________________ mitk-users mailing list mitk-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/mitk-users _______________________________________________ mitk-users mailing list mitk-users@lists.sourceforge.net https://lists.sourceforge.net/lists/listinfo/mitk-users