Hi MITK-Diffusion team,
I am new to MITK-diffusion and trying to analyze IVIM data of the brain for 
brain metastasis. I am exporting the data as dicom from MRI scanner. I tried 
many time to import the dicom data through Dicom import tool but it is always 
gives me this error message:
2908.66 core.mod.diffusionCore.diffusiondicomfilereader: Retrieved 2 outputs.
2908.67 core.mod.diffusionCore.diffusiondicomfilereader: Output 1  Got vendor: 
Siemens Healthineers image type 
DERIVED\PRIMARY\DIFFUSION\TRACEW\NORM\DIS2D\MFSPLIT
2908.67 core.mod.diffusionCore.diffusiondicomfilereader ERROR: No header reader 
for given vendor.
2908.79 core.mod.diffusionCore.diffusiondicomfilereader WARNING: Unable to 
retrieve vendor/image information from 
//umh.edu/data/Radiology/Common/Nada/IVIM/sub026/dwi/DICOM/22092815/32370000\DICOMDIR
Output 2 is not valid, skipping analysis.
2908.79 Timing information
No probes have been created

I also tried to convert the dicom images into nifti file format and change the 
extension in .fsl or fslgz but could not import them into MITK-diffusion 
toolbox.

Any input or suggestion would be appreciated.

Best,
Ayman

_______________________________________________
mitk-users mailing list
mitk-users@lists.sourceforge.net
https://lists.sourceforge.net/lists/listinfo/mitk-users

Reply via email to