Hi,

I was wondering if anyone has managed to get the preload_app and SIGUSR2
combination working well with upstart?

My issue currently is that when I perform a SIGUSR2 against the master,
check everything's working and close off the old master, upstart then
attempts to restart it because the original PID/binary are no longer
running.

What is the correct way of handling this? In my opinion, should unicorn
not always be using the same master process and just spawning additional
children/cycling them? Else the above functionality will never work with
upstart, which will be replacing init.

Thanks,
Rob