Hi, I would like to enquire on integration of Monit and Heartbeat. I have created a pair of primary/slave servers such that primary will failover to the slave, but slave will not failback to primary when something goes wrong. I wanted this behaviour so that there will not be any flipflop cases in situation where it is not recoverable such as internet connection goes offline for a long period of time.
Meanwhile I'm using hb_standby utility as a way to initiate a failover from the primary. I wanted by scripts on the pair of servers to be consistent for easy maintainance, hence both monitrc script will exec hb_standby based on service failure scenarios. This is causing a flipflop situation, is there any other means of initiating a failover such that if a failover is initiated in heartbeat, it will honour the settings in ha.cf where if auto_failback is off, then even if the service died in the slave server, failback will not occur? I assume hb_standby will not work in the current situation ? Anyone with solutions ? Thanks -- __________________________________________________________________ David, KWOK Tai Wei Senior Software Engineer Mail Ranger - A Division of Ufinity Pte Ltd Email : [EMAIL PROTECTED] Web : www.ufinity.com, www.mailranger.com Main : +65 6779 9398 DID : +65 6779 9398 FAX : +65 6873 0289 Address: 12 Ayer Rajah Crescent, Singapore 139941 -- To unsubscribe: http://lists.nongnu.org/mailman/listinfo/monit-general