Please read monit manual:
http://www.tildeslash.com/monit/doc/manual.php#alert_messages
The "set alert ..." is global for all services - you can use
local/per-service alert when needed. You can also filter the events (the
particular event type which is related to monit start/stop/reload is
called "instance").
Martin
monit user wrote:
I am trying to add a secondary email for just certain conditions but
that email is receiving an alert when I restart monit, too. I only want
that address to receive mail for the specific situations where I use it.
I can't figure out what I am doing wrong, never used this feature of
monit before...
set alert [EMAIL PROTECTED]
set alert [EMAIL PROTECTED]
check system 10.0.0.10
if loadavg (5min) > 5.0 2 times within 3 cycles then alert
alert
[EMAIL PROTECTED]
...
check process httpd with pidfile /var/run/httpd.pid
if failed host 10.0.0.10 port 80 then alert
alert
[EMAIL PROTECTED]
--
To unsubscribe:
http://lists.nongnu.org/mailman/listinfo/monit-general
--
To unsubscribe:
http://lists.nongnu.org/mailman/listinfo/monit-general