Changed by [EMAIL PROTECTED]

http://bugzilla.ximian.com/show_bug.cgi?id=81446

--- shadow/81446        2007-08-22 10:37:05.000000000 -0400
+++ shadow/81446.tmp.1461       2007-08-23 09:27:39.000000000 -0400
@@ -12,12 +12,13 @@
 ReportedBy: [EMAIL PROTECTED]               
 QAContact: [EMAIL PROTECTED]
 TargetMilestone: ---
 URL: 
 Cc: 
 Summary: PrivateBinPath used incorrectly ?
+BugsThisDependsOn: 57612
 
 In System.Web, the PrivateBinPath of the domain is apparently not used 
 correctly.
 
 First of all, the PrivateBinPath is a list of directories relative to the 
 ApplicationBase of the domain, not an absolute path. 
@@ -123,6 +124,17 @@
     <probing privatePath>
 
 is semicolon separated as well:
 
 http://msdn2.microsoft.com/en-us/library/823z9h8w.aspx
 
+
+------- Additional Comments From [EMAIL PROTECTED]  2007-08-23 09:27 -------
+I've modified the recent changes a bit today, so that PrivateBinPath
+is not used for bin or Bin lookups at all anymore. Right now we look
+at bin and/or Bin directly and unconditionally. PrivateBinPath is set
+to either bin or Bin:bin depending on whether we run under Windows (or
+with MONO_IOMAP) or on Unix. I also have a patch that adds support for
+<runtime><assemblyBinding><probing> to the runtime - attached to bug
+#57612
+I will modify sys.web to use semicolons once #57612 is closed, as the
+change depends on the patch attached there being applied.