[resend, now with a From: which Listar should like]
On 2001/11/01 18:11, Marco Catunda <[EMAIL PROTECTED]> wrote: > On Tue, 2001-10-02 at 11:36, Ytsejam wrote: > > Dear all, > > > > I collected flow data from a router. > > Now, I got a new router, so I change rrd to collect from the new router & a > > new interface. > > I also copy the old serial interface .rrd & .meta file and rename to the > > new interface, so that I can keep the history data. > > It works, but because the counter is different between old router/interface > > and new one. > > When rrd collect data from the new interface and update into the old .rrd > > file, > > it generates a huge peak! > > > > Is there any way to remove the peak and keep my flow data history ? > > > What do you think about it? > Is there another better solution? I don't know how to remove the peak once you've generated it. When I transferred rrd data from .log or stone-age rrd to my current system I used something like "rrdtool update N:U:U:U:U" to reset the COUNTER settings to Unknown. (btw, is anyone interested in my log->rrd script which tries to re-generate the MAX as well as the averages ?) /ol -- / Otmar Lendl ([EMAIL PROTECTED]) | Phone: +43 1 89933-0 (-533 fax) \ \ KPNQwest/AT Systems Engineer | Diefenbachgasse 35 A-1150 Wien / -- Unsubscribe mailto:[EMAIL PROTECTED] Help mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/rrd-developers WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi
