Hi Peter,
Peter Bailey wrote:
>       In any case, addendum to my last message, I will be making an option
>       to attempt to display numbers instead of exponent information on the y
>       axis.
> 
>       So again, anybody who's started on any of this or has any feedback,
>       please shoot.
> 

I modified the log-autoscaler to work with arbitrary ranges for version 
1.0.40. I use it for monitoring Ultra-High-Vacuum pressure ranging from 
1000 down to 1e-9 mbar.

But there was not enough time to adapt this to a development version.


Regards, Beat

-- 
Beat ZAHND
Physics Institute
University of Bern                   phone  +41 31 631 3466
Sidlerstrasse 5                      fax    +41 31 631 4405
CH-3012 Bern (Switzerland)  mailto:[EMAIL PROTECTED]

        http://www.phim.unibe.ch/rosina/rosina.html
                 http://rosetta.esa.int/


-- Attached file removed by Ecartis and put at URL below --
-- Type: text/plain
-- Size: 11k (11554 bytes)
-- URL : http://www.ee.ethz.ch/~slist/p/log-autoscale.patch


--
Unsubscribe mailto:[EMAIL PROTECTED]
Help        mailto:[EMAIL PROTECTED]
Archive     http://www.ee.ethz.ch/~slist/rrd-developers
WebAdmin    http://www.ee.ethz.ch/~slist/lsg2.cgi