>Hello, >Have everybody used mrtg with a 3com SuperStack 3 Switch 3300TM ? >it isn't in the compatibility list ! >if someone has success this thing, what is the manipulation ? >King Regards ! >Erwan
Not used the TM, but some of the others in the 3300 range. They will response to CFGmaker quite happily. Everything is an interface. The interface numbering is a little strange, in that Ports take the Unit number in the stack and concatenates it with the actual port number, so Port 04 on unit 2 is interface 204 VLAN1 has a low number (<100), other VLANs (if defined) have high numbers. Unit# 41 (ie 141, 241 etc) monitor each switch individually. Cannot find CPU or temperature anywhere. Regards Peter -- Unsubscribe mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/mrtg FAQ http://faq.mrtg.org Homepage http://www.mrtg.org WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi