I had measured the error packet of a WAN circuit by the following CONFIG on the VLAN interface of MSFC (Catalyst6500). -----ERROR IN-------- #ifInErrors(14) & ifInUcastPkts(11) + #Dummy & ifInNUcastPkts(12) + #Dummy & ifInDiscards(13) + #Dummy & ifInErrors(14) + #Dummy & ifInUnknownProtos(15) Target[target_name]: ( .1.3.6.1.2.1.2.2.1.14.interface_num&.1.3.6.1.2.1.2.2. 1.11.interface_num:[EMAIL PROTECTED] + .1.3.6.1.2.1.15.2.0&.1.3.6.1.2.1.2.2.1.12.interface_num:[EMAIL PROTECTED] _name + .1.3.6.1.2.1.15.2.0&.1.3.6.1.2.1.2.2.1.13.interface_num:[EMAIL PROTECTED] _name + .1.3.6.1.2.1.15.2.0&.1.3.6.1.2.1.2.2.1.14.interface_num:[EMAIL PROTECTED] _name + .1.3.6.1.2.1.15.2.0&.1.3.6.1.2.1.2.2.1.15.interface_num:[EMAIL PROTECTED] _name ) * 300
-----ERROR OUT-------- #ifOutErrors(20) & ifOutUcastPkts(17) + #Dummy & ifOutNUcastPkts(18) + #Dummy & ifOutDiscards(19) + Target[target_name]: ( .1.3.6.1.2.1.2.2.1.20.interface_num&.1.3.6.1.2.1.2.2. 1.17.interface_num:[EMAIL PROTECTED] + .1.3.6.1.2.1.15.2.0&.1.3.6.1.2.1.2.2.1.18.interface_num:[EMAIL PROTECTED] _name + .1.3.6.1.2.1.15.2.0&.1.3.6.1.2.1.2.2.1.19.interface_num:[EMAIL PROTECTED] _name ) * 300 ------------- However, by this method, it turns out that it cannot measure and changed to measurement in the physical port of Catalyst6500. All that matters here is that OID (.1.3.6.1.2.1.15.2.0) of Dummy does not exist in Catalyst6500. OID which always returns 0 is known? (.1.3.6.1.2.1.15.2.0=bgpLocalAs) Is there any method using OID of Dummy? Thanks /K Kaji -- Unsubscribe mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/mrtg FAQ http://faq.mrtg.org Homepage http://www.mrtg.org WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi