Thanks for the prompt reply! I thought this was the general area as well but that OID is not available. Here's what I get when I walk 1.3.6.1.4.1.9.5.1.1:
> snmpwalk -c community -v 2c 10.94.0.2 1.3.6.1.4.1.9.5.1.1 SNMPv2-SMI::enterprises.9.5.1.1.8.0 = INTEGER: 1 SNMPv2-SMI::enterprises.9.5.1.1.19.0 = INTEGER: 5 SNMPv2-SMI::enterprises.9.5.1.1.20.0 = Timeticks: (856864558) 99 days, 4:10:45.58 SNMPv2-SMI::enterprises.9.5.1.1.24.0 = INTEGER: 2 SNMPv2-SMI::enterprises.9.5.1.1.25.0 = INTEGER: 2 SNMPv2-SMI::enterprises.9.5.1.1.32.1.1.1 = INTEGER: 1 SNMPv2-SMI::enterprises.9.5.1.1.32.1.2.1 = INTEGER: 1 SNMPv2-SMI::enterprises.9.5.1.1.32.1.3.1 = INTEGER: 5 SNMPv2-SMI::enterprises.9.5.1.1.32.1.4.1 = Timeticks: (856864558) 99 days, 4:10:45.58 SNMPv2-SMI::enterprises.9.5.1.1.53.0 = INTEGER: 1 SNMPv2-SMI::enterprises.9.5.1.1.67.0 = INTEGER: 2 Any ideas? Many thanks for all your assistance. -Samson -----Original Message----- From: Walid Khalil [mailto:[EMAIL PROTECTED] Sent: Thursday, August 07, 2003 2:19 PM To: Samson Martinez Subject: RE: [mrtg] 6513 Sup2 OID I believe that's what you are looking for : sysConfigSupervisorModuleNo (OID 1.3.6.1.4.1.9.5.1.1.52) from the CISCO-STACK-MIB Name: sysConfigSupervisorModuleNo Type: OBJECT-TYPE OID: 1.3.6.1.4.1.9.5.1.1.52 Full path: iso(1).org(3).dod(6).internet(1).private(4).enterprises(1).cisco(9).work group(5).ciscoStackMIB(1).systemGrp(1).sysConfigSupervisorModuleNo(52) Module: CISCO-STACK-MIB Parent: systemGrp Prev sibling: sysStartupConfigSourceFile Next sibling: sysStandbyPortEnable Numerical syntax: Integer (32 bit) Base syntax: INTEGER Composed syntax: INTEGER Status: current Max access: read-write Size list: 1: 1..2 Description: Indicates the supervisor module (active or standby, if applicable) that the MIB objects sysConfigRegister, sysBootVariable, sysStartupConfigSource, and sysStartupConfigSourceFile are specified for. This MIB object is only supported by the supervisor modules with the flash file system feature support. The default value for this MIB object is set to the active supervisor module number. Regards, Walid -----Original Message----- From: Samson Martinez [mailto:[EMAIL PROTECTED] Sent: Thu 8/7/2003 1:20 PM To: [EMAIL PROTECTED] Cc: Subject: [mrtg] 6513 Sup2 OID Hello, Does anyone happen to know what OIDs, if any, would allow me to track the active/standby status of Supervisory 2 modules. These are installed in a Cisco 6513 switch. Thanks! -Samson -- Unsubscribe mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/mrtg FAQ http://faq.mrtg.org Homepage http://www.mrtg.org WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi -- Unsubscribe mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/mrtg FAQ http://faq.mrtg.org Homepage http://www.mrtg.org WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi