On Thu, 2003-10-02 at 02:07, von dan wrote: > My router interface bw is 40704 Kbit. I have 2 MRTG Linux box , one > stated max speed 5088.0kBytes and the other 1250kBytes. My collegues > said the correct speed is 1250kBytes. cfgmaker just looks at the bandwidth statement. With a bandwidth of 40704, the correct value for maxbytes is 5088.
However, if your actual speed is less than the bandwidth statement, and you can't change the bandwidth statement because of some routing hack you are doing, then you have to either manually modify your maxbytes statement, or write a template that will determine the proper value for you. If you have just a couple of atm interfaces, I'd probably write a template that picked out those particular interfaces and hard coded the values. If you have a large number of traffic shaped connections, then I would probably create a database in mysql to track those things, then write a template that looks up the appropriate CIR and PIR from the database and sets maxbytes and absmax accordingly. I suppose you could look into the CISCO-QOS-mumble-MIB and find some stats that would give you PIR and CIR, and you could write a template that polled those using snmp. > The only way I can change the max speed is to edit the *.cfg file. > But whenever I re-run my cfgmaker script, I get 5088.0kBytes. I want > to find out who is correct, 5088 or 1250. -- Daniel J McDonald, CCIE 2495, CNX Austin Energy -- Unsubscribe mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/mrtg FAQ http://faq.mrtg.org Homepage http://www.mrtg.org WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi