Here is my config file. It is getting somethig from UPS, but there are untrue values. What i do wrong?? Anybody?? Marcin
#--------------------------------------------------------------- Target[ups1-noc2.1]:1.3.6.1.4.1.318.1.1.1.3.2.1.0&1.3.6.1.4.1.318.1.1.1.4.2.1.0:public@<IP> MaxBytes[ups1-noc2.1]: 250 Title[ups1-noc2.1]: UPS1 At NOC2: Current AC Line Voltage PageTop[ups1-noc2.1]: <H1>Current Line Voltage for NOC2 UPS1</H1> WithPeak[ups1-noc2.1]: wmy Options[ups1-noc2.1]:absolute, gauge, nopercent Ylegend[ups1-noc2.1]:Voltage ShortLegend[ups1-noc2.1]: Volts LegendI[ups1-noc2.1]: Input Voltage LegendO[ups1-noc2.1]: Output Voltage Legend1[ups1-noc2.1]: Input Voltage Legend2[ups1-noc2.1]: Output Voltage Legend3[ups1-noc2.1]: Max Input Voltage Legend4[ups1-noc2.1]: Max Output Voltage #--------------------------------------------------------------- Target[ups1-noc2.2]: 1.3.6.1.4.1.318.1.1.1.3.2.3.0&1.3.6.1.4.1.318.1.1.1.3.2.2.0:public@<IP> MaxBytes[ups1-noc2.2]: 250 Title[ups1-noc2.2]: UPS1 At NOC2: Min and Max AC Line Voltage PageTop[ups1-noc2.2]: <H1>Min and Max Line Voltage for NOC2 UPS1</H1> WithPeak[ups1-noc2.2]: wmy Options[ups1-noc2.2]:absolute, gauge, nopercent Ylegend[ups1-noc2.2]:Voltage ShortLegend[ups1-noc2.2]: Volts LegendI[ups1-noc2.2]: Min Voltage LegendO[ups1-noc2.2]: Max Voltage Legend1[ups1-noc2.2]: Min Voltage Legend2[ups1-noc2.2]: Max Voltage Legend3[ups1-noc2.2]: Max Min Voltage Legend4[ups1-noc2.2]: Max Max Voltage #--------------------------------------------------------------- Target[ups1-noc2.3]: 1.3.6.1.4.1.318.1.1.1.3.2.5.0&1.3.6.1.4.1.318.1.1.1.3.2.5.0:public@<IP> MaxBytes[ups1-noc2.3]: 32 Title[ups1-noc2.3]: UPS1 At NOC2: Last Reason On-Battery PageTop[ups1-noc2.3]: <H1>Last Reason On-Battery for NOC2 UPS1</H1> See the <a href="reasons.txt">reasons</a> for on-battery. Options[ups1-noc2.3]:absolute, gauge Ylegend[ups1-noc2.3]:Cause Code ShortLegend[ups1-noc2.3]: LegendI[ups1-noc2.3]: Cause LegendO[ups1-noc2.3]: Cause Legend1[ups1-noc2.3]: Cause Legend2[ups1-noc2.3]: Cause #--------------------------------------------------------------- Target[ups1-noc2.4]: 1.3.6.1.4.1.318.1.1.1.2.2.1.0&1.3.6.1.4.1.318.1.1.1.2.2.1.0:public@<IP> <IP>MaxBytes[ups1-noc2.4]: 100 Title[ups1-noc2.4]: UPS1 at NOC2: Battery Capacity PageTop[ups1-noc2.4]: <H1>Battery Capacity for NOC2 UPS1</H1> WithPeak[ups1-noc2.4]: wmy Options[ups1-noc2.4]:absolute, gauge Ylegend[ups1-noc2.4]:Capacity ShortLegend[ups1-noc2.4]: Percent LegendI[ups1-noc2.4]: Capacity LegendO[ups1-noc2.4]: Capacity Legend1[ups1-noc2.4]: Capacity, Percent Legend2[ups1-noc2.4]: Capacity, Percent Legend3[ups1-noc2.4]: Max Capacity, Percent Legend4[ups1-noc2.4]: Max Capacity, Percent #--------------------------------------------------------------- Target[ups1-noc2.5]: 1.3.6.1.4.1.318.1.1.1.2.2.2.0&1.3.6.1.4.1.318.1.1.1.2.2.2.0:public@<IP> MaxBytes[ups1-noc2.5]: 100 Title[ups1-noc2.5]: UPS1 at NOC2: Battery Temperature PageTop[ups1-noc2.5]: <H1>Battery Temperature for NOC2 UPS1</H1> WithPeak[ups1-noc2.5]: wmy Options[ups1-noc2.5]:absolute, gauge Ylegend[ups1-noc2.5]:Temperature LegendI[ups1-noc2.5]: Temperature LegendO[ups1-noc2.5]: Temperature ShortLegend[ups1-noc2.5]: Degress Legend1[ups1-noc2.5]: Degrees Legend2[ups1-noc2.5]: Degrees Legend3[ups1-noc2.5]: Max Degrees Legend4[ups1-noc2.5]: Max Degrees #--------------------------------------------------------------- Target[ups1-noc2.6]: 1.3.6.1.4.1.318.1.1.1.3.2.4.0&1.3.6.1.4.1.318.1.1.1.4.2.2.0:public@<IP> MaxBytes[ups1-noc2.6]: 250 Title[ups1-noc2.6]: UPS1 At NOC2: AC Frequency PageTop[ups1-noc2.6]: <H1>In and Out Frequency for NOC2 UPS1</H1> WithPeak[ups1-noc2.6]: wmy Options[ups1-noc2.6]:absolute, gauge, nopercent Ylegend[ups1-noc2.6]:Frequency ShortLegend[ups1-noc2.6]: Hertz LegendI[ups1-noc2.6]: Input Frequency LegendO[ups1-noc2.6]: Output Frequency Legend1[ups1-noc2.6]:Input Frequency, Hertz Legend2[ups1-noc2.6]:Output Frequency, Hertz Legend3[ups1-noc2.6]:Max Input Frequency, Hertz Legend4[ups1-noc2.6]:Max Output Frequency, Hertz #--------------------------------------------------------------- Target[ups1-noc2.7]: 1.3.6.1.4.1.318.1.1.1.4.2.4.0&1.3.6.1.4.1.318.1.1.1.4.2.4.0:public@<IP> MaxBytes[ups1-noc2.7]: 250 Title[ups1-noc2.7]: UPS1 At NOC2: Output Current PageTop[ups1-noc2.7]: <H1>Output Current for NOC2 UPS1</H1> WithPeak[ups1-noc2.7]: wmy Options[ups1-noc2.7]:absolute, gauge, nopercent Ylegend[ups1-noc2.7]:Current ShortLegend[ups1-noc2.7]: Amps LegendI[ups1-noc2.7]: Current LegendO[ups1-noc2.7]: Current Legend1[ups1-noc2.7]:Current, Amps Legend2[ups1-noc2.7]:Current, Amps Legend3[ups1-noc2.7]:Max Current, Amps Legend4[ups1-noc2.7]:Max Current, Amps #--------------------------------------------------------------- Target[ups1-noc2.8]: 1.3.6.1.4.1.318.1.1.1.4.2.3.0&1.3.6.1.4.1.318.1.1.1.4.2.3.0:public@<IP> MaxBytes[ups1-noc2.8]: 10000 Title[ups1-noc2.8]: UPS1 at NOC2: Load PageTop[ups1-noc2.8]: <H1>Load for NOC2 UPS1</H1> WithPeak[ups1-noc2.8]: wmy Options[ups1-noc2.8]:gauge, nopercent ShortLegend[ups1-noc2.8]: Percent Ylegend[ups1-noc2.8]:Load LegendI[ups1-noc2.8]: Load LegendO[ups1-noc2.8]: Load Legend1[ups1-noc2.8]:Load, Percent Legend2[ups1-noc2.8]:Load, Percent Legend3[ups1-noc2.8]:Max Load, Percent Legend4[ups1-noc2.8]:Max Load, Percent #--------------------------------------------------------------- -- Unsubscribe mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/mrtg FAQ http://faq.mrtg.org Homepage http://www.mrtg.org WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi