Marcin, Please can you be little more specific? Which of the oid's give values that are "untrue"? What values are returned and what do you think they should be?
Jan. -----Original Message----- From: Marcin Sypien [mailto:[EMAIL PROTECTED] Sent: Thursday, October 30, 2003 11:27 AM To: mrtg Subject: [mrtg] question Here is my config file. It is getting somethig from UPS, but there are untrue values. What i do wrong?? Anybody?? Marcin #--------------------------------------------------------------- Target[ups1-noc2.1]:1.3.6.1.4.1.318.1.1.1.3.2.1.0&1.3.6.1.4.1.318.1.1.1. 4.2.1.0:public@<IP> MaxBytes[ups1-noc2.1]: 250 Title[ups1-noc2.1]: UPS1 At NOC2: Current AC Line Voltage PageTop[ups1-noc2.1]: <H1>Current Line Voltage for NOC2 UPS1</H1> WithPeak[ups1-noc2.1]: wmy Options[ups1-noc2.1]:absolute, gauge, nopercent Ylegend[ups1-noc2.1]:Voltage ShortLegend[ups1-noc2.1]: Volts LegendI[ups1-noc2.1]: Input Voltage LegendO[ups1-noc2.1]: Output Voltage Legend1[ups1-noc2.1]: Input Voltage Legend2[ups1-noc2.1]: Output Voltage Legend3[ups1-noc2.1]: Max Input Voltage Legend4[ups1-noc2.1]: Max Output Voltage #--------------------------------------------------------------- Target[ups1-noc2.2]: 1.3.6.1.4.1.318.1.1.1.3.2.3.0&1.3.6.1.4.1.318.1.1.1.3.2.2.0:public@<IP> MaxBytes[ups1-noc2.2]: 250 Title[ups1-noc2.2]: UPS1 At NOC2: Min and Max AC Line Voltage PageTop[ups1-noc2.2]: <H1>Min and Max Line Voltage for NOC2 UPS1</H1> WithPeak[ups1-noc2.2]: wmy Options[ups1-noc2.2]:absolute, gauge, nopercent Ylegend[ups1-noc2.2]:Voltage ShortLegend[ups1-noc2.2]: Volts LegendI[ups1-noc2.2]: Min Voltage LegendO[ups1-noc2.2]: Max Voltage Legend1[ups1-noc2.2]: Min Voltage Legend2[ups1-noc2.2]: Max Voltage Legend3[ups1-noc2.2]: Max Min Voltage Legend4[ups1-noc2.2]: Max Max Voltage #--------------------------------------------------------------- Target[ups1-noc2.3]: 1.3.6.1.4.1.318.1.1.1.3.2.5.0&1.3.6.1.4.1.318.1.1.1.3.2.5.0:public@<IP> MaxBytes[ups1-noc2.3]: 32 Title[ups1-noc2.3]: UPS1 At NOC2: Last Reason On-Battery PageTop[ups1-noc2.3]: <H1>Last Reason On-Battery for NOC2 UPS1</H1> See the <a href="reasons.txt">reasons</a> for on-battery. Options[ups1-noc2.3]:absolute, gauge Ylegend[ups1-noc2.3]:Cause Code ShortLegend[ups1-noc2.3]: LegendI[ups1-noc2.3]: Cause LegendO[ups1-noc2.3]: Cause Legend1[ups1-noc2.3]: Cause Legend2[ups1-noc2.3]: Cause #--------------------------------------------------------------- Target[ups1-noc2.4]: 1.3.6.1.4.1.318.1.1.1.2.2.1.0&1.3.6.1.4.1.318.1.1.1.2.2.1.0:public@<IP> <IP>MaxBytes[ups1-noc2.4]: 100 Title[ups1-noc2.4]: UPS1 at NOC2: Battery Capacity PageTop[ups1-noc2.4]: <H1>Battery Capacity for NOC2 UPS1</H1> WithPeak[ups1-noc2.4]: wmy Options[ups1-noc2.4]:absolute, gauge Ylegend[ups1-noc2.4]:Capacity ShortLegend[ups1-noc2.4]: Percent LegendI[ups1-noc2.4]: Capacity LegendO[ups1-noc2.4]: Capacity Legend1[ups1-noc2.4]: Capacity, Percent Legend2[ups1-noc2.4]: Capacity, Percent Legend3[ups1-noc2.4]: Max Capacity, Percent Legend4[ups1-noc2.4]: Max Capacity, Percent #--------------------------------------------------------------- Target[ups1-noc2.5]: 1.3.6.1.4.1.318.1.1.1.2.2.2.0&1.3.6.1.4.1.318.1.1.1.2.2.2.0:public@<IP> MaxBytes[ups1-noc2.5]: 100 Title[ups1-noc2.5]: UPS1 at NOC2: Battery Temperature PageTop[ups1-noc2.5]: <H1>Battery Temperature for NOC2 UPS1</H1> WithPeak[ups1-noc2.5]: wmy Options[ups1-noc2.5]:absolute, gauge Ylegend[ups1-noc2.5]:Temperature LegendI[ups1-noc2.5]: Temperature LegendO[ups1-noc2.5]: Temperature ShortLegend[ups1-noc2.5]: Degress Legend1[ups1-noc2.5]: Degrees Legend2[ups1-noc2.5]: Degrees Legend3[ups1-noc2.5]: Max Degrees Legend4[ups1-noc2.5]: Max Degrees #--------------------------------------------------------------- Target[ups1-noc2.6]: 1.3.6.1.4.1.318.1.1.1.3.2.4.0&1.3.6.1.4.1.318.1.1.1.4.2.2.0:public@<IP> MaxBytes[ups1-noc2.6]: 250 Title[ups1-noc2.6]: UPS1 At NOC2: AC Frequency PageTop[ups1-noc2.6]: <H1>In and Out Frequency for NOC2 UPS1</H1> WithPeak[ups1-noc2.6]: wmy Options[ups1-noc2.6]:absolute, gauge, nopercent Ylegend[ups1-noc2.6]:Frequency ShortLegend[ups1-noc2.6]: Hertz LegendI[ups1-noc2.6]: Input Frequency LegendO[ups1-noc2.6]: Output Frequency Legend1[ups1-noc2.6]:Input Frequency, Hertz Legend2[ups1-noc2.6]:Output Frequency, Hertz Legend3[ups1-noc2.6]:Max Input Frequency, Hertz Legend4[ups1-noc2.6]:Max Output Frequency, Hertz #--------------------------------------------------------------- Target[ups1-noc2.7]: 1.3.6.1.4.1.318.1.1.1.4.2.4.0&1.3.6.1.4.1.318.1.1.1.4.2.4.0:public@<IP> MaxBytes[ups1-noc2.7]: 250 Title[ups1-noc2.7]: UPS1 At NOC2: Output Current PageTop[ups1-noc2.7]: <H1>Output Current for NOC2 UPS1</H1> WithPeak[ups1-noc2.7]: wmy Options[ups1-noc2.7]:absolute, gauge, nopercent Ylegend[ups1-noc2.7]:Current ShortLegend[ups1-noc2.7]: Amps LegendI[ups1-noc2.7]: Current LegendO[ups1-noc2.7]: Current Legend1[ups1-noc2.7]:Current, Amps Legend2[ups1-noc2.7]:Current, Amps Legend3[ups1-noc2.7]:Max Current, Amps Legend4[ups1-noc2.7]:Max Current, Amps #--------------------------------------------------------------- Target[ups1-noc2.8]: 1.3.6.1.4.1.318.1.1.1.4.2.3.0&1.3.6.1.4.1.318.1.1.1.4.2.3.0:public@<IP> MaxBytes[ups1-noc2.8]: 10000 Title[ups1-noc2.8]: UPS1 at NOC2: Load PageTop[ups1-noc2.8]: <H1>Load for NOC2 UPS1</H1> WithPeak[ups1-noc2.8]: wmy Options[ups1-noc2.8]:gauge, nopercent ShortLegend[ups1-noc2.8]: Percent Ylegend[ups1-noc2.8]:Load LegendI[ups1-noc2.8]: Load LegendO[ups1-noc2.8]: Load Legend1[ups1-noc2.8]:Load, Percent Legend2[ups1-noc2.8]:Load, Percent Legend3[ups1-noc2.8]:Max Load, Percent Legend4[ups1-noc2.8]:Max Load, Percent #--------------------------------------------------------------- -- Unsubscribe mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/mrtg FAQ http://faq.mrtg.org Homepage http://www.mrtg.org WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi Het ministerie van Sociale Zaken en Werkgelegenheid sluit elke aansprakelijkheid uit in verband met het niet juist, onvolledig of niet tijdig overkomen van de informatie in deze e-mail. Aan dit bericht kunnen geen rechten worden ontleend. Dit bericht is alleen bestemd voor de geadresseerde. Indien dit bericht niet voor u bestemd is, verzoeken wij u dit onmiddellijk aan ons te melden en de inhoud van het bericht te vernietigen. -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- The ministry of Social Affairs and Employment is not liable for any incorrect or incomplete transmission of the information in this e-mail or for any delay in its receipt. This message shall not constitute any obligations. This message is intended solely for the addressee. If you have received this message in error, please inform us immediately and delete its content. -- Unsubscribe mailto:[EMAIL PROTECTED] Archive http://www.ee.ethz.ch/~slist/mrtg FAQ http://faq.mrtg.org Homepage http://www.mrtg.org WebAdmin http://www.ee.ethz.ch/~slist/lsg2.cgi