On 13/04/07, Amos Shapira <[EMAIL PROTECTED]> wrote:
On 13/04/07, Eric Brander <[EMAIL PROTECTED]> wrote: First - thanks for taking the time to answer my questions.
It looks like the configuration HAS changed but a few days earlier and somehow it broke only now - I added a couple of Windows disk monitoring configurations using cfgstoragemaker, which sets defaults using _ and ^ targets without reseting them. Among other things it sets the counter type to "gauge", which was left there when my counter was read. Adding "Options[_]:" to reset to the default (as well as the other stuff) seems to have fixed the problem. I found this from watching the debug log and reading the MRTG source to decipher rateup command line arguments. Cheers, --Amos
_______________________________________________ mrtg mailing list [EMAIL PROTECTED] https://lists.oetiker.ch/cgi-bin/listinfo/mrtg