Thanks Jan, but I will not be helped though I use Target[mypoll]:1.2.1.12.2.4.4.1.14/x.x.x.x:[EMAIL PROTECTED]
Any body familiar with cisco uBR-7200 CMTSs ? I would appreciate any further advices. TIA, Gaurav > Well that would do for the interface's statistics I guess but what I am > facing here is. I have to graph MRTG for the values such as No of modems > online, The RF peripherals, in the device so I guess there isn't anything > except OIDs that I can use. > > lets say as the ifindex has ifindex.1 ifindex.2 and so on for the > interfaces..I have a few MIBs that also has .1 .2 etc as the leaf OIDs for > them...and after reboots they are changing I had not had this type of > experiences before... > >> To avoid problems with broken graphs MRTG offers some methods to >> identify >> the right oid. > > I had identified the correct OID for the ones I have been graphing. > Identifying the right OID wont help I guess because though the OID is > identified and is polled, the leaf OID that contains the values are > changed across reboots. So if I graph a correct OID and after a reboot the > leaf OID changes than I think I will get errors for sure. > > Someone did recommend me to use "snmp-server ifindex persist" in my > devices...I want to know does that help me with the changing OIDs. > > Regards, > > Gaurav > > >> >> -----Original Message----- >> From: [EMAIL PROTECTED] >> [mailto:[EMAIL PROTECTED] On Behalf Of gaurav >> Sent: Friday, August 31, 2007 9:11 PM >> To: [email protected] >> Subject: [mrtg] OIDs changing. >> >> >> Dear all, >> >> Recently I was amazed to see few things in the devices I was using MRTG >> for. >> >> First, I have two cisco uBR 7200 with same IOS version and same model >> but >> the OIDs in them for same datas to are to be retrieved are different in >> the leaf OIDs whereas the branch OID is the same. >> >> i mean if 1.3.2.1.2.1.2.3.1.2.1.2 was for one than >> 1.3.2.1.2.1.2.3.1.2.1.9 was for the other.. >> >> Second thing is one of the device got automatically rebooted because of >> some power failure lately, and i was unable to see MRTG graphs for few >> of >> the datas polled. Upon further diagnose i found that the leaf OIDs have >> increased with two >> >> i mean if 1.3.2.1.2.1.2.3.1.2.1.2 was the OID that was polled than >> after >> the reboot it wasnt existing and 1.3.2.1.2.1.2.3.1.2.1.4 was the one >> that was providing the necessary values. >> >> Has any one came across this type of situations before...please do >> share.. >> >> Does the OIDs get changed so abnormally or is it because of some faults >> in the device. >> >> TIA, >> >> Gaurav >> >> >> >> >> _________________________________________________________ >> >> Dit bericht kan informatie bevatten die niet voor u is bestemd. Indien u >> niet de geadresseerde bent of dit bericht abusievelijk aan u is >> toegezonden, wordt u verzocht dat aan de afzender te melden en het >> bericht >> te verwijderen. De staat aanvaardt geen aansprakelijkheid voor schade, >> van >> welke aard ook, die verband houdt met risico's verbonden aan het >> elektronisch verzenden van berichten. >> _________________________________________________________ >> >> This message may contain information that is not intended for you. If >> you >> are not the addressee or if this message was sent to you by mistake, you >> are requested to inform the sender and delete the message. The state >> accepts no liability for damage of any kind resulting from the risks >> inherent in the electronic transmission of messages. >> _________________________________________________________ > > > -- > Gaurav Ghimire > Support Dept. > Subisu Cablenet Pvt. Ltd. > Baluwatar, Kathmandu. > -- Gaurav Ghimire Support Dept. Subisu Cablenet Pvt. Ltd. Baluwatar, Kathmandu. -- Gaurav Ghimire Support Dept. Subisu Cablenet Pvt. Ltd. Baluwatar, Kathmandu. _______________________________________________ mrtg mailing list [email protected] https://lists.oetiker.ch/cgi-bin/listinfo/mrtg