On Monday 16 March 2009, Sumanta Das wrote:
> hi all,
> time interval-- 5 min,
[snip...]

> now i am not getting any common thing in between graph and log, how the max
> in/out and average in/out current in/out is calculating i could not find
> out.....

Have a look at the paragraph talking about the "gauge" option here: 
http://oss.oetiker.ch/mrtg/doc/mrtg-reference.en.html

It explains how averaging works and gauge is *not* used.  In this case it is 
the difference in the counters averaged over 5 minutes.
-- 
Regards,
Mick