On Tue, 2009-04-14 at 12:49 +0500, Kashif Siddiq Patoli wrote: > Hi, Thanks a lot for the support. > > One last thing: How to figure out the exact RP value (i think it is > indexing)? > > Also, I am monitoring the temperature using OID > 1.3.6.1.4.1.9.9.13.1.3.1.3.1 &.3; but I am not sure if it is showing > me the correct inlet and outlet temperature (I am observing the > temperature graph with constant amplitude without any variation).
I'm not familiar with the EnvMonitorMib (That was someone else.) With The Entity Sensor Mib, the Sensor name is listed in EntPhysicalName, e.g: CISCO-ENTITY-SENSOR-MIB::entSensorType.9003 8 CISCO-ENTITY-SENSOR-MIB::entSensorType.9004 8 CISCO-ENTITY-SENSOR-MIB::entSensorType.9007 8 CISCO-ENTITY-SENSOR-MIB::entSensorType.9008 8 CISCO-ENTITY-SENSOR-MIB::entSensorType.9009 8 [mcdonal...@ldap ~]$ snmpwalk -v 3 -l authpriv -u foo -a sha -x aes -3k 0xd6 -3K 0x47 -m CISCO-ENTITY-SENSOR-MIB router.example.com ENTITY-MIB::entPhysicalName.9003 "module 6 outlet temperature Sensor" ENTITY-MIB::entPhysicalName.9004 "module 6 inlet temperature Sensor" ENTITY-MIB::entPhysicalName.9007 "module 6 VDB outlet temperature Sensor" ENTITY-MIB::entPhysicalName.9008 "module 6 VDB inlet temperature Sensor" ENTITY-MIB::entPhysicalName.9009 "module 6 VDB device-1 temperature Sensor" > > Regards, > > Kashif > > On Mon, Apr 13, 2009 at 5:52 PM, McDonald, Dan > <[email protected]> wrote: > On Sat, 2009-04-11 at 17:09 +0200, Simon Leinen wrote: > > Mick writes: > > > On Saturday 11 April 2009, Kashif Siddiq Patoli wrote: > > > > For RP CPU readings, you could use > OLD-CISCO-SYS-MIB::avgBusy5.0 > > (1.3.6.1.4.1.9.2.1.58.0). If you want to access all CPUs > (RP, SP, > > DFCs), use CISCO-PROCESS-MIB::cpmCPUTotal5minRev > > (1.3.6.1.4.1.9.9.109.1.1.1.1.8) > > > That's probably correct. Cisco has wavered a bit on support > of the Rev > variants, so it might be cpmCPUTotal5min instead. Depends on > the > versions of code involved. > > > DOM/transceiver monitoring values such as optical Tx and Rx > power can be > > accessed using CISCO-ENTITY-SENSOR-MIB, in particular > entSensorValue > > (1.3.6.1.4.1.9.9.91.1.1.1.1.4). The indexing is somewhat > tricky because > > it refers to the highly structured SENSOR-MIB. > > > Not all optics produce this value, but for those that do this > is a very > interesting thing to monitor. It's also somewhat annoying in > that it is > reported as a negative number, in centiBels. To support the > negative > numbers, you have to perform an rrdtool tune on the .rrdfiles > - Someday > I'll write that into cfgmaker... > > I wrote a template to perform the indexing and change the unit > to > deciBels. It's posted on Steve Shipway's site. The salient > portion is: > # > # Look for dBm meters - probably interesting > > snmpMIB_to_OID("/usr/share/snmp/mibs/ENTITY-SENSOR-MIB.my"); > > snmpMIB_to_OID("/usr/share/snmp/mibs/CISCO-ENTITY-SENSOR-MIB-V1SMI.my"); > my (@est) = snmpwalk($router,$v3opt,'entSensorType'); > foreach my $esti (@est) { > my ($tinstance,$ttype) = ($esti =~ /(\d+):(.+)$/) ; > next if $ttype != 14; > my (@estv) = snmpwalk($router, > $v3opt,'entSensorThresholdValue.'.$tinstance); > my %thresh; > foreach my $estvi (@estv) { > my ($thin,$value) = ($estvi =~ /(\d+):(.+)$/) ; > $thresh{$thin} = $value; > }; > my $maxsize = $thresh{1}+10; > my ($sens_name) = snmpget($router, > $v3opt,'entPhysicalName.'.$tinstance); > my $sens_descr .= ' '.$sens_name; > my $target_name=$router_name.".signal".$tinstance; > $target_lines .= <<SIGNAL > > #-------------------------------------------------------------------------------------- > # Signal Strength > > Target[$target_name]: > entSensorValue.$tinstance&entSensorValue.$tinstance:$router > SnmpOptions[$target_name]: $v3options > YLegend[$target_name]: dB > Options[$target_name]: gauge, noi, nopercent > Directory[$target_name]: $directory_name > MaxBytes[$target_name]: $maxsize > ShortLegend[$target_name]: dB > Factor[$target_name]: .1 > routers.cgi*ShortDesc[$target_name]: $sens_name > routers.cgi*Options[$target_name]: nototal > bb*host[$target_name]: $router_name > bb*svc[$target_name]: signal > bb*red[$target_name]: $thresh{4}:$thresh{1} > bb*yellow[$target_name]: $thresh{3}:$thresh{2} > Legend1[$target_name]: dB > WithPeak[$target_name]: ymw > Title[$target_name]: $sysname $sens_descr > PageTop[$target_name]: <H1>$sysname $sens_descr </H1> > <TABLE> > <TR><TD>System:</TD><TD>$sysname </TD></TR> > <TR><TD>Location:</TD><TD>$syslocation </TD></TR> > </TABLE> > SIGNAL > ; > } > > > > The temperatures could also be retrieved using > entSensorValue, > > > So, the code above could be re-used, just change the > next if $ttype != 14; > line to whatever ttype is used for the temperature monitors, > then change > labels and units to match. > > > -- > Daniel J McDonald, CCIE #2495, CISSP #78281, CNX > Austin Energy > http://www.austinenergy.com > > > _______________________________________________ > mrtg mailing list > [email protected] > https://lists.oetiker.ch/cgi-bin/listinfo/mrtg > > > > > -- > Kashif Siddiq Patoli -- Daniel J McDonald, CCIE #2495, CISSP #78281, CNX Austin Energy http://www.austinenergy.com
signature.asc
Description: This is a digitally signed message part
_______________________________________________ mrtg mailing list [email protected] https://lists.oetiker.ch/cgi-bin/listinfo/mrtg