You can't poll negative values.  Maybe someone can offer an alternative, but 
MRTG itself cannot handle a negative polling value.

________________________________
From: [email protected] [[email protected]] On Behalf 
Of Kashif Siddiq Patoli [[email protected]]
Sent: Wednesday, April 22, 2009 4:58 AM
To: [email protected]
Subject: [mrtg] Differnet Poll Values for Similar Type of Interfaces

Hi,

I am observing differnet poll values for POS 0/0/0/0 and POS 0/1/0/0 while 
monitoring optical power (DOM). The output shows following tx/rx power
1). Tx power = 0.4930 mW, -3.1 dBm

2). Tx power = 0.5400 mW, -2.7 dBm

The polled values are:

For 1),
1240390321 2538 2538
1240390321 2538 2538 2538 2538
1240390019 2538 2538 2538 2538
1240389900 2538 2538 2538 2538
1240389600 2538 2538 2538 2538

For 2),

1240390321 45 45
1240390321 45 45 45 45
1240390019 45 45 45 45
1240389900 45 45 45 45
1240389600 45 45 45 45

Plz suggest if there is something wrong in the cfg as both the interfaces are 
using same OID on the same router.


Target[optical_power]: 
1.3.6.1.4.1.9.9.91.1.1.1.1.4.34&1.3.6.1.4.1.9.9.91.1.1.1.1.4.34:[email protected]

YLegend[optical_power]: dB

Options[optical_power]: gauge, noi, nopercent, growright

MaxBytes[optical_power]: 7000

factor[optical_power]: -0.001

YTics[optical_power]: 7

YTicsFactor[optical_power]: 0.001

ShortLegend[optical_power]: dB

Legend1[optical_power]: dB

Title[optical_power]: Optical Power Measurement for STM-64

PageTop[optical_power]: <H1>Optical Power Measurement for STM-64 </H1>

--
Kashif
_______________________________________________
mrtg mailing list
[email protected]
https://lists.oetiker.ch/cgi-bin/listinfo/mrtg

Reply via email to