On Fri, 2009-08-28 at 08:43 +0200, Gerd Bitzer wrote: > Hello listmembers, > > So I believe that's not a problem with MRTG, but with the config of > the 6509. This leads me to my question, does anybody have some hints > what could cause this behaviour, or a checklist of relevant settings > of the 6509 which could be checked ? > > By the way, the 6509 has IOS (tm) MSFC2 Software (C6MSFC2-JSV-M), > Version 12.1(27b)E4, RELEASE SOFTWARE (fc3) installed.
Wow, that's pretty old hybrid code. In hybrid mode, you will get odd results from the MSFC, due to packet offloading by the PFC. Try polling the switch supervisor instead. Also, the MFSC2 is rapidly approaching end of life. You may want to bite the bullet and plan an upgrade to sup720 or sup32, hopefully at least running native-mode, although I personally prefer modularity mode (boots way faster). I've not had any weirdness with SNMP on sup720's. -- Daniel J McDonald, CCIE # 2495, CISSP # 78281, CNX www.austinenergy.com