On Tue, 2009-12-29 at 09:44 -0500, Sankung Sawo wrote: > Dear MRTG support, > > I have difficulty running my Master.cfg file. I created the file but > when I run it the html and PNG image files of the devices are not > updated; only the log file associated with the master.log is updated > and no errors are recorded. The master.cfg file contents as: > > ========= > > Forks: 20 > > Include: sw203.cfg > > Include: sw205.cfg > > Include: c2811-r1.cfg > > ============== end of master.cfg file. > > The included files are in the same folder as the master.cfg file.
I think the include statements have to have the complete path, but it should throw errors if it can't find the file. You may need to define workdir: in master.cfg -- Daniel J McDonald, CCIE # 2495, CISSP # 78281, CNX www.austinenergy.com _______________________________________________ mrtg mailing list [email protected] https://lists.oetiker.ch/cgi-bin/listinfo/mrtg
