On 9/13/10 9:55 AM, "Matthew Ayres" <[email protected]> wrote:
> I have a Sonicwall 4060 with vlans configured on two of its interfaces > cfgmaker picks up the interface as whole but does not pick up the sub > interfaces Are the sub-interfaces in the snmp table? If you walk the ifTable, do the sub-interfaces have entries? If not, then open a product request with Sonicwall to add that information. If so, have a look at ifType. If the type code is not defined in cfgmaker, it might ignore it. Cfgmaker around line 456 is where the logic begins for determining if it is worth monitoring a particular ifType.... > if you could point me in the right direction that would be great > -- Daniel J McDonald, CCIE # 2495, CISSP # 78281